●LZKM1-10、24开启式电流互感器
●LZKM1-10、24 open-core current transformer

额定电流比,准确级及其额定负载如下表所示:
Rated ratio,Accuracy class and Rated burden following table:
|
型号 Type |
LZKM1-10C |
LZKM1-10P |
|
用 途
Purpose |
测量电流互感器
Measuring current transformer |
保护电流互感器
Protective current transformer |
|
电流比
Ratio
I1/I2 |
准确级及其额定负载(VA)
Acc. class and rated burden |
准确级及其额定负(VA)
Acc. class and rated burden |
|
0.5 |
1.0 |
3.0 |
10P15 |
10P10 |
10P5 |
|
300/1 |
2 |
2.5 |
3.5 |
|
|
1 |
|
400/1 |
2.5 |
3 |
3.75 |
|
1.25 |
2.5 |
|
500/1 |
2.5 |
3.5 |
5 |
1 |
1.5 |
3.75 |
|
600/1 |
2.5 |
3.75 |
5 |
1.5 |
2 |
3.75 |
|
300/5 |
2 |
3.75. |
5 |
|
1.5 |
2.5 |
|
400/5 |
2.5. |
3.75 |
5 |
|
2 |
3.75 |
|
500/5 |
3.75 |
5 |
7.5 |
2 |
2.5 |
5 |
|
600/5 |
5 |
7.5 |
10 |
2 |
2.5 |
5 |
外型尺寸 Outine drawing Ø60 × Ø112 × H52

●LZKM2-10、24开启式电流互感器
●LZKM2-10、24 open-core current transformer
额定电流比,准确级及其额定负载如下表所示:
Rated ratio,Accuracy class and Rated burden following table
:
|
型号Type |
LZKM2-10C |
LZKM2-10P |
LZKM2-10CP |
|
用 途
Purpose |
测量电流互感器
Measuring current
transformer |
保护电流互感器
Protective current
transformer |
测量,保护电流互感器
Double winding current transfo |
|
电流比
Ratio
I1/I2 |
准确级及其额定负载(VA)
Acc. class and rated burden |
准确级及其额定负(VA)
Acc. class and rated burden |
复合准确级及其额定负载(VA)
Composite acc class and ratedburden |
|
0.2 |
0.5 |
1.0 |
10P15 |
10P10 |
10P5 |
0.5 |
1.0 |
10P10 |
10P5 |
|
50/1 |
|
1 |
1.5 |
|
|
1 |
|
|
|
|
|
75/1 |
|
2 |
|
|
1 |
2 |
|
|
|
|
|
100/1 |
|
2.5 |
|
|
1.5 |
3 |
|
1 |
|
1 |
|
150/1 |
|
2.5 |
|
|
2 |
|
|
1.5 |
1 |
2 |
|
200/1 |
|
3 |
|
|
2.5 |
|
1 |
2 |
1.5 |
3 |
|
300/1 |
|
3.5 |
|
2 |
3 |
|
1.5 |
2.5 |
2 |
|
|
400/1 |
|
3.5 |
|
2.5 |
3.5 |
|
2 |
|
2 |
|
|
500/1 |
|
5 |
|
3 |
5 |
|
2.5 |
|
2.5 |
|
|
600/1 |
|
7.5 |
|
5 |
7.5 |
|
3 |
|
3 |
|
|
75/5 |
|
|
2.5 |
|
|
1.5 |
|
|
|
|
|
100/5 |
|
2.5 |
|
|
|
2.5 |
|
|
|
|
|
150/5 |
|
2.5 |
|
|
|
2.5 |